Air conditioning, heating and refrigeration institute. This guide focuses solely on industrial refrigeration systems, which we define in the following broad. Certificates of completion for nonaia members are available on request. Ammonia is one alternative refrigerant for new, replacement, and existing refrigeration system designs, where compatible. Technical and energetic appraisal of ammonia refrigerating. This code of practice is intended to apply within the united kingdom to systems where the motors driving the compressors have a total installed power of more than 25kw, including any standby. Ammonia refrigeration fundamentals graphic products. For ammonia systems, iiar bulletin also addresses the subject of safety valves. Anhydrous ammonia as a refrigerant where is ammonia used as a refrigerant. The new and improved iiar 2 is the definitive design safety standard of the ammonia refrigeration industry. At this point in time, there is no specific qualification for ammonia refrigeration in new. An introduction to ammonia refrigeration systems ashrae is a registered provider with the american institute of architects continuing education systems. From preventative maintenance to emergency ammonia refrigeration service, we can provide all your industrial ammonia refrigeration service needs. Read online operation of ammonia refrigeration systems book pdf free download link book now.
Ammonia refrigeration systems operate in a similar manner to fluorocarbon systems, but have several key differences. An output file gives the performance results as well as suggestions on how to. Get your team aligned with all the tools you need on one secure, reliable video platform. Supplemental risk management program guidance for ammonia refrigeration facilities. Distributed low charge refrigeration systems 20190107 4 overview. The suction gas for the refrigeration system might be from a storage tank or from a pipeline, the refrigeration system is to liquefy the gas and send the liquid to other facility or to a storage tank. This manual summarizes the requirements of environmental and safety laws for anhydrous ammonia refrigeration system operators. The quantity of ammonia in systems varies from less than 5,000 pounds to more than 250,000 pounds. Introduction chapter 1 introduction courtesy of frick background this guide identifies and discusses best practices for making industrial refrigeration systems both energyefficient and productive.
Guidelines for ammonia refrigeration plant equipment. Risk assessment of refrigeration systems using a2l flammable. The differences are somewhat obvious but offer just enough differences to challenge technicians from either field. Figure 2a below is one thermodynamic representation ofa refrigeration cycle showing the relationship between the pressure and enthalpy of the refrigerant ammonia as it flows through the system. Manual for refrigeration servicing introduction technicians. Thus, the basics of refrigeration technique have not been presented. Some ammoniabased systems are similar to designs used in hvacr svstems that use halocarbons. An ammonia refrigeration system, like all vaporcompression refrigeration systems, are made up of a number of components working together. Sep 03, 2008 an open cycle refrigeration system is that the system is without a traditional evaporator. Safe management of ammonia refrigeration systems january 2016 page 2 of 49 foreword this guidance has been developed by industry, following the withdrawal of hses publication pm81, to give clear current crosssector guidance on the safe management of ammonia refrigeration systems. In the past, this was done by collecting ice in the winter and using its specific heat to cool as the ice melted.
T he refrigerant of the system is an open flow and is. Condenser, head pressure control, ammonia refrigeration. The newest storage facilities utilize multilevel, fully. Ammonia nh3 is the least expensive of all the commonly used industrial refrigerants. Throughout its period of use as a refrigerant, nh3 has proven to be ideally suited to this purpose. In the control loop of refrigeration systems and used as an active decision. Any water in the system would freeze and obstruct piping, so ammonia refrigeration systems must use anhydrous ammonia without water or other impurities. Guidelines for startup, inspection, and maintenance of ammonia mechanical refrigerating systems 1. Risk assessment of refrigeration systems using a2l. Basic closed cycle refrigeration system has changed very little since then.
Accompanying the growth of the refrigeration system was a consequent growth in the ammonia charge of the facility. The explosion range for ammonia is 16% to 25% mixed with air. Commodity storage manual, the refrigeration research foundation, washington. Ultra low charge ammonia systems for cold storage applications. Industrial refrigeration system basics, in this video well be looking at how ammonia refrigeration systems work, starting at the basics to. When 1 pound of ice melts, it absorbs 144 btu, as latent energy. Instruments for industrial ammonia refrigeration plant on vimeo. It is an ebook for people who are involved in training and. Essentially, the ammonia is the chemical that is contained within the system to remove heat from an area, and then dissipate it in another area. Design documents never specify all necessary details, so. Ammonia systems are now available in compactsmaller systems. Ammonia has a high affinity for moisture, and is readily absorbed by many materials.
George ronn is the senior manager of refrigerant compliance and. Industrial refrigeration systems explore solutions danfoss. Ammonia refrigeration systems anw sb 17 0 valves vessels systems controls refrigeration systems should only be serviced by a qualified technician. With over 160 years combined experience in ammonia systems, we are well staffed to handle any project. Industrial refrigeration system basics ammonia refrigeration. Appendix b ammonia refrigeration application data b2 ammonia data book may 2008 alternatively, figure b1 has been generated which allows one to quickly look up a cfm ton for a series of more commonly encountered refrigeration cycle conditions. Nh3 refrigeration systems tolerate considerable amounts of moistureother. Nh3 is thermodynamically 3 to 10% more efficient compared with hcfc22 and hcfc4a. Operation of ammonia refrigeration systems pdf book manual. General the refrigerant ammonia nh 3 is the definitive operating fluid for industrial use. Centralized and builtup, as opposed to commercial refrigeration.
Technical and energetic appraisal of ammonia refrigerating systems for industrial use 0. Advantages of low charge ammonia systems for operator. Throughout its period of use as a refrigerant, nh 3 has proven to be ideally suited to this purpose. While you will not usually find an ammonia based system inside a home ammonia is a very toxic substance, and the refrigerators are very expensive, they are used in factories that need large refrigeration devices that can cool substances very quickly. Ammonia refrigeration systems have traditionally employed evaporators supplied with liquid by either gravity flooding with surge drums, or pumped overfeed either with. Distributed low charge refrigeration systems 20190107 6 how best to locate them. Ammonia piping should conform to asme standard b31. The owner of an ammonia refrigeration system is responsible for compliance with all regulations and must not depend on these guidelines as an allinclusive reference for regulatory requirements applicable to ammonia refrigeration plants. The highest levels of efficiency in these systems are achieved through a. Instruments for industrial ammonia refrigeration plant on.
While you will not usually find an ammoniabased system inside a home ammonia is a very toxic substance, and the refrigerators are very expensive, they are used in factories that need large refrigeration devices that can cool substances very quickly. For more information see the latest revision of phillips safety bulletin sgrv. Safe management of ammonia refrigeration systems january 2016 page 5 of 49 introduction 1. Specifies criteria for materials, design parameters, marking and testing of valves and strainers used in closed circuit ammonia refrigeration systems. Another distinguishing feature is that industrial refrigeration systems usually consist of parallel. This article is an abstract of that document and its presentation at the conference1.
American society of heating, refrigerating and airconditioning engineers, inc. Baker refrigeration is a fullservice industrial refrigeration designbuild contractor. Low ammonia charge refrigeration systems for cold storage. It continues to be the refrigerant of choice in many food processing. Operation of ammonia refrigeration systems pdf book. The vicious wet circle the actual cause of many problems in industrial ammonia refrigeration plants is water contamination of the ammonia itself. All books are in clear copy here, and all files are secure so dont worry about it. Because copper and copperbearing materials are attacked by ammonia, they are not used in ammonia piping systems. Heat is added to the ammonia in the evaporation step, increasing its enthalpy. Ammonia r717 in the vast majority of cases, with some r22 applications system type.
Download operation of ammonia refrigeration systems book pdf free download link or read online here in pdf. Institute of refrigeration safety code of practice for ammonia refrigerant. Ammonia piping should conform to asme standard b, refrigerant piping reprinted by permission from ashrae handbookrefrigeration. Accident prevention and response manual for anhydrous ammonia refrigeration system operators. There are 3 federal agencies which all have their eyes on the cold storage industry, at least where it relates to ammonia refrigeration in general, and ammonia charge, in specific. S a f e t y g u i d e f o r a m m o n i a r e f r i g e r a t i o n i n n e w z e a l a n d p a g e safety guide for ammonia refrigeration systems in new zealand. Jul 17, 2017 ammonia refrigeration systems operate in a similar manner to fluorocarbon systems, but have several key differences. Distributed refrigeration systems are growing in popularity and site installations, so understanding this new technology and how to apply it is the purpose of this document.
Together, this means the refrigeration system uses a large amount. Welcome to the manual for refrigeration servicing technicians. Ammonia1 has been used as a refrigerant in industrial applications for more than 150 years. Installation is greatly simplified because the compact skid unit is factory build and tested. Ammonia refrigeration systems are a series of interconnected vessels and piping that compress and pump ammonia to one or more rooms to cool, chill, or freeze them to specific temperatures. Ammonia refrigeration systems with 10,000 pounds approximately 2000 gallons or more of ammonia are a covered process subject to the requirements of the occupational. Danfoss industrial refrigeration solutions offer highly efficient and reliable refrigeration systems optimized for ammonia and other natural refrigerants. Some ammonia based systems are similar to designs used in hvacr svstems that use halocarbons. Safety and health topics ammonia refrigeration standards. Often, the only visible signs in the plant are just the result or a symptom.
Enforcement alert for anhydrous ammonia refrigeration. Safety guide for ammonia refrigeration in new zealand. The specific requirements for a particular system must be. End users of ammonia refrigeration systems are increasingly interested in reducing the charge of ammonia in evaporators and in the overall system in the interest of minimizing. The physics of vaporcompression refrigeration require the system to use enough pressure to compress the gas into a liquid. Large industrial refrigeration systems typically use ammonia as a refrigerant of choice because. Low ammonia charge refrigeration systems for cold storage white paper.
It is intended that this chapter be used as a general reference source and that in all cases, recommended practices issued by equipment manufacturers and suppliers take precedence over these. Institute of refrigeration safety code of practice for. Application handbook automatic controls for industrial refrigeration systems. The twin hazards of toxicity and flammability normally associated with ammonia also do not appear in the list of circumstances although approximately 90% of the companys business is in the supply and ongoing maintenance of ammonia systems. American society of heating, refrigerating and air. The iiar has developed the low charge ammonia refrigeration management armlc summary guide to provide a briefing on recommendations for commercial, retail food, and light industrial end users, engineers, equipment manufacturers and contractors that desire to implement a management program for low charge ammonia refrigeration systems with. Early refrigerants included ammonia, sulfuric ether, sulfur dioxide, methyl chloride. Absorption machines of capacities in the range of 101500 tons are available. Always observe proper safety procedures when servicing a refrigeration system. Feedback ammonia and refrigeration page 3 contents glossary introduction history p. Technical and energetic appraisal of ammonia refrigerating systems. Ansiiiar 3, american national standard for ammonia refrigeration valves. Low charge packaged systems 4 pounds per ton of refrigeration 2,200 lbs ultra low charge packaged systems 0.
The low charge ammonia refrigeration system has a capacity up to 75 tons while still maintaining a less than epa regulated 100 lbs of ammonia. Because ammonias properties are best suited to large refrigeration systems, there is likely to be a large amount of ammonia in any system that uses it. It has remained the main refrigerant used in industrial refrigeration systems because of its superior thermodynamic properties and low cost. Typical systems the best way to undelstand ammonia refrigeration sys. Industrial refrigeration ammonia and co2 applications danfoss. An open cycle refrigeration system is that the system is without a traditional evaporator. Industrial refrigeration best practices guide 1 chapter 1. Credit earned on completion of this program will be reported to ces records for aia members.
Automatic controls for industrial refrigeration systems. Steel piping, fittings, and valves of the proper pressure rating are suitable for ammonia gas and liquid. R717, ammonia is a very popular refrigerant because this refrigerant provides all the desirable features except the toxicity and the flammability ratings. This guidance may go further than the minimum needed. Obviously, the more units used per room the more expensive the installation will be. Similar to a penthouse configuration, the key is locating the equipment such that the air can be evenly distributed throughout the facility. Even though modern ammonia refrigeration systems are designed to avoid any accidental release of ammonia, leaks and spills continue to occur each year, causing injuries, deaths and loss of millions of dollars in product.
1276 1520 4 312 343 1099 25 414 716 1159 68 612 1025 1025 598 1320 109 896 268 879 436 433 595 416 1099 775 289 325 630 450 803 703 289 1029